Meba mcb MB8 type
Product Description
Meba mcb MB8 type can protect and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switch-gear panels, railway and marine application.Applicable to terminal and pin/fork type busbar connection,Protection against both overload and short circuit High short-circuit capacityMeba mcb MB8 type
Technical parameters
Tropicalization | Relative Humidity | °C | 93% RH at 25°C |
Room Temperature | °C | 10°C a 60°C | |
Electrical Properties | Rated at 40°C | A | 6/10/16/20/25/32/40/50/63 |
Rated operating voltage at 40°C | Vac | 240/415 | |
Nominal Frequency | Hz | 50/60 | |
Interrupting Capacity at 230V | kA | 6 | |
Operating temperature | °C | 40 | |
Degree of Protection | IP20 | ||
Number of poles | 1/2/3/4 | ||
Conductor cross section (minimum allowable) | mm2 | 25 | |
Minimum number of power moves | 4000 | ||
Minimum number of mechanical operations | 10000 | ||
Operation curve | B/C/D | ||
Current Trip Curve | A | 5 a 10 In | |
Characteristic Intervention | attach | ||
Type Of Assembly | FOR RIEL DIN 35 mm | ||
Features | MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D ) | ||
BIMETAL: ensures the breaker trip when overloaded. | |||
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. |
Meba mcb MB8 type
can protect and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switch-gear panels, railway and marine application.Applicable to terminal and pin/fork type busbar connection,Protection against both overload and short circuit High short-circuit capacity
Feature:
MAGNETIC COIL:ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.