Huangqijia Industrial Zone, Liushi, Wenzhou, Zhejiang, China.
Huangqijia Industrial Zone, Liushi, Wenzhou, Zhejiang, China.
Huangqijia Industrial Zone, Liushi, Wenzhou, Zhejiang, China.
Mon To Fri 8AM to 5PM
Circuit Breaker

Meba mcb rcd MB49

Product Description

Meba mcb rcd MB49 major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Meba mcb rcd MB49

Technical parameters

ropicalization Relative Humidity °C 93% RH at 25°C
Room Temperature °C 10°C a 60°C
Electrical Properties Rated at 40? A 6/10/15/20/30/40/50/63
Rated operating voltage at 40? Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature °C -5°C a +40°C
Degree of Protection   IP20
Number of poles   1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves   4000
Minimum number of mechanical operations   6000
Operation curve   B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention   attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb rcd MB49

major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Inquiry Form - lucy from Meba
If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day.
All Electrical work must be done by a qualified licensed electrician.