Meba Thermal Magnetic Release Moulded Case Breakers NS-250N-3P

Product Description

Meba Thermal Magnetic Release Moulded Case Breakers NS-250N-3P NS series Compact MCCB the rated insulating voltage is 750V, suitable for AC 50Hz(60Hz), rated working voltage 690V or below, rated working current is 12.5A to 1250A of circuit.

Meba Thermal Magnetic Release Moulded Case Breakers NS-250N-3P

Specification:

Type Pole No. Rated insulating voltage(V) Rated operating voltage(V) Rated ultimate short circuit breaking capacity Icu(KA) at 380/415V Rated services short circuit breaking capacity Ics at 380/415V(KA) Operation performace Utiliza-tim Category
ON OFF
NS-100N 3, 4 pole 750 690 and below 25 25 1500 8500 A
NS-100H 70 70
NS-100L 150 150
NS-160N 36 36 1000 7000
NS-160H 70 70
NS-160L 150 150
NS-250N 36 36 1000 7000
NS-250H 70 70
NS-250L 150 150
NS-400N 45 45 1000 4000
NS-400H 70 70
NS-400L 150 150
NS-630N 45 45 1000 4000
NS-630H 70 70
NS-630L 150 450
NS-1250N 3 pole 50 37.5 1000 4000
NS-1600N 50 37.5

Note:
1. The N-pole breaker has no protection which closing and opening with the other three poles.
2. The type of thermal magnetic for NS-400/630 has no four poles.

Trip unit main technical parameter:

Type Rated Current In(A) Note
NS-100 12.5,16,20,25,32,40,50,63,80,100 T adjustable(0.8-1In)
M adjustable(5-10In)
NS-160 16,20,25,32,40,50,68,80,100,125,160
NS-250 160,180,200,225,250
NS-400 315,350,400
NS-630 400,500,630
NS-1250 800,1000,1250 T adjustable(0.8-1In)
M fixed
NS-1600 1000,1250,1600

Meba Thermal Magnetic Release Moulded Case Breakers NS-250N-3P

Application:

1. NS series Compact MCCB the rated insulating voltage is 750V, suitable for AC 50Hz(60Hz), rated working voltage 690V or below, rated working current is 12.5A to 1250A of circuit.

2. Used in distributing electric energy, and non-frequent breaking in the normal conditions, protecting the current & equipment from overload&under voltage, circuit breaker with rated frame current 400A or below can be used in motor’s non-frequent start, breaking during working, protecting motor from overload, short circuit&under-voltage.

3. The product conforms to IEC60947-2 standard.

Classification:

1. Installation way: Mounted vertically, Horizontal installation;
2. By use of circuit breaker usage: Distribution protection, Motor protection;
3. According to the mode of wiring points: Front panel wiring, Back panel wiring , Plug-in connection;
4. According to the mode of operation: direct operating handle, External turning the handle operations, electric operation;
5. By release type distinction: instantaneous action release (magnetic release), thermal + electromagnetic release (duplex); electronic release;
6.  Poles Number: 3poles, 4poles;

Accessories Rated operating voltage Consumption For type
Pick-up Seal-in
Shunt release(MX) 24V   <10VA   <5VA  NS-100 ~  630
100V
220/230V
380/400V
Under-voltage release(UN) 220/230V <10VA <5VA
380/400V
Accessories Rated operating voltage Rated operating current For type
AC12 AC15
Auxiliary contact(OF) 380/400V 6 3 NS-100 ~  630
Alarm contact(AL) 380/400V 6 3

Rotary handle

-A. Direct rotary handle
Degree of protection:IP40
Function:
1) suitability for isolation
2) indication of three positions 0(off) I(on) and tripped
3) press ush to trip?button, can trip-free
4) visibility of and access to trip unit settings
5) the circuit breaker can be locked in the off position by one to three padlocks, diameter 5 to 8mm(not supplied)
-B. Extended rotary handle
Degree of protection:IP55
Function:
1) Suitability for isolation
2) Indication of three positions 0(off) I(on) and tripped
3) Visibility of and access to trip unit settings when the door is open
4) Door opening prevented when circuit breaker is on
5) The circuit breaker can be locked in the off position by one to three padlocks, diameter 5 to 8mm(not supplied). Locking prevents opening of the switchboard door
Installation: Circuit breaker may be mounted vertically, horizontally or flat on their back without any derating of characteristics.
Fix: Mounting on backplate, mounting on rails
Connection: Front panel connection, black panel connection, plug-in connection